Calibrated fibre optic Distributed Temperature Sensing (DTS) data, Maisbich, Luxemburg Parent item: Calibrated fibre optic Distributed Temperature Sensing (DTS) data, Maisbich Explanation of the calibration procedure of the DTS derived temperatures in the Maisbich river, Luxembourg. Note that it only corrects offsets orriginating from the DTS device (Halo, Sensornet, UK). It does NOT correct for periods when the cable is not properly submerged in the stream. The DTS obtained temperatures were calibrated with five independent temperature loggers (TidbiT v2 Temp logger, HOBO, USA) located along the cable at 26, 395, 931, 1111 and 1270 m from the DTS desktop computer, respectively. Note that the investigated branch lies between 717 (V-notch weir Q3) and 1282 m (V-notch weir Q4) from the desktop computer. For each Tidbit temperature logger, which measured at a 6 min interval, a linear relation was determined between the DTS derived temperature and the difference between the TidbiT …